● 100ms data reponse
● Single-phase: 240/480V, Three-phase:3×230/400V、3×277/480V
● 80A, 120A, 200A, 300A, 3×80A, 3×120A, 3×200A, 3×300A
● RS485(MODBUS-RTU)
● Set parameters
● LCD display
● kWh Class 0.5
● DIN 35 mm

    OVERVIEW

    ADL series DIN-rail mounted multi functional electric energy meter is an intelligent instrument mainly designed for new energy power generation systems such as photovoltaic grid-connected system, micro inverter system, energy storage system, AC coupling system, etc. The product has the features of sampling, metering and monitoring power parameters,communicating with an inverter or an energy management system (EMS), realizing the functions of preventing reverse flow, regulating power generation, charging and discharging batteries according to real-time power and accumulated electric energy, and realizing bidirectional metering and household distributed photovoltaic energy management.

    MAIN PARAMETERS

    Grid

    Three-phase four-wire, three-phase three-wire, single-phase three-wire

    Voltage

    Single-phase

    240/480V

    Three-phase

    3×230/400V、3×277/480V

    Overload

    1.2 times rating (continuous)

    2 times the rating for 1 second

    Power consumption

    <0.2VA

    Current

    Input current

    80A, 120A, 200A, 300A, 3×80A, 3×120A, 3×200A, 3×300A

    Overload

    1.2 times rating (continuous)

    2 times the rating for 1 second

    Consumption

    <0.2VA

    Accuracy class

    Class 0.5S

    Power

    Active, reactive, apparent power, error ±0.5℅

    Grid frequency

    45~65Hz, error ±0.5%

    Response rate

    ≤1s (electrical energy)

    Electric energy

    Active energy :Class B (split current transformer) /Class C (closed current transformer)

    Reactive energy (Class 2 accuracy)

    Electromagnetic compatibility

    Electrostatic discharge immunity class III

    Electrical fast transient burst immunity class IV

    Surge (shock) immunity Class IV

    Power frequency withstand voltage

    Between communication and signal input, AC4kV 1min

    Insulation resistance

    Input and output terminals to casing >100MΩ

    Communication

    Interface and communication protocol

    RS485 interface and Modbus RTU protocol

    Communication address range

    Modbus RTU:1~ 247

    Baud rate

    Support 1200bps-38400bps

    Environment

    Operating temperature

    -40℃~+70℃

    Storage temperature

    -40℃~+70℃

    Relative humidity

    ≤95℅ (without condensation)

    Altitude

    ≤3000m

    FUNCTIONS

    dimensiontzb

    APPLICAITON

    1705901510544dc8
    17059015170119ut
    1705901524432k7n
    1705901533921jep

    APPLICAITON SCENARIOS

    1705901510544dc8
    17059015170119ut

    121qnl

    ONE-STEP DIRECT SOLUTION

    1705901838856f2l

    LORA-BASED INDIRECT SOLUTION

    1705901846676oha

    WIRING DIAGRAM

    wiring-1xpu

    3P4W connected via CTs

    wiring-2jdh

    3P3W connected via CTs
    (this connection is limited to Three-phase equilibrium)
    (meter set as 3P4W)

    wiring-3iti

    3P3W connection via transformer (meter set as 3P3W)

    wiring-42sj

    single-phase three-wire connection through cts

    INSTALLATION INSTRUCTION

    installationbho
    Download_file
    [Certificate 2023.06.21] CE Certificate of ADW300 Series
    Download_file
    [Certificate 2023.06.21] CE-RED Certificate of ADW300 Series
    Download_file
    [Certificate 2023.06.21] IEC Certificate ADW300 Series
    Download_file
    [Certificate 2023.06.21] LVD Certificate of ADW300 Series
    Download_file
    [Datasheet 2023.06.21] ADW300 3-phase Wireless Energy Meter
    Download_file
    [Instruction 2023.08.31] ADW300 Common FAQ & Trouble Shooting
    Download_file
    [Instruction 2023.08.31] ADW300 Keypad Configuration Manual