English
Leave Your Message
ADL400 Three-phase Energy Meter

Din Rail Energy Meter

Products Categories
Featured Products

ADL400 Three-phase Energy Meter

  • Measurement 3-phase AC kWh, kVarh, U, I, P, Q, S, PF, F and etc
  • Accuracy 0.5% (kWh)
  • Frequency 45~65Hz
  •  Rated Voltage 3x380~456Vac L-L (direct connect); 3x100~120Vac L-L (via PTs)
  • Rated Current 3x10(80)A AC (direct connect); 3x1(6)A AC (via CTs)
  • Communication RS485 (MODBUS-RTU)
  • Multi-rate 4 Tariff Rates and etc
  • Data Function Frozen Data,Max Demand,etc
  • Harmonic  2~31st and total Harmonic
  •  Standard&Certificate IEC; CE;CE-MID; EAC

OVERVIEW

Acrel ADL400 three phase din rail energy meter is an intelligent instrument designed mainly for electric energy statistics and management needs of power systems, industrial and mining enterprises, and public facilities. The product has the advantages of high precision, small size, and convenient installation.  It can measure all power parameters, with 2~31 sub-harmonic and total harmonic content detection. With RS485 communication interface and optional MODBUS-RTU protocol, the power meter can be widely used in various control systems, SCADA systems, and energy management systems.

MAIN PARAMETERS

Voltage Input

Rated voltage

3X57.7/100V, 3X 220/380V, 3X 380/660V, 3X 100V, 3X 380V,3 X 660V

Reference frequency

50Hz

Consumption

<0.5VA (Each phase)

Current Input

Basic current

3X 1(6)A: 3X 1(6)A ( ADW 3o0w),3 x 20( 100)OA ( ADW 300w)

Starting current

1%o Ib (Class 0.5S), 4%o Ib (Class 1)

Consumption

<1VA (Each phase)

Auxiliary Power

Power Supply

AC 85~265V

Power consumption

<2W

Measurement performance

Standard

IEC 62053-22:2003,IEC 62053-21:2003

Active energy accuracy

Class 0.5S (ADW300),Class 1 (ADW300W)

Temperature accuracy

土2C

Pulse

Width of pulse

80420ms

Pulse con stant

6400imp/kWh,400imp/kWh

Communication

Wireless

Transmission on 470MHz and max imum distance in open space is 1km;  4G;LORA;WIFI;2G; NB:

Infrared communication

The constant baud rate is 1200

Interface

RS485(A、B)

Connection mode

Shielded twisted pair conductors

Protocol

 MODBUS-RTU

Main Functions

1c64

Main Parameters

2v9t

 Main Features

Diverse Electric Parameters Measurement
● kWh (3-phase positive Kilowatt-hours)
● kVarh (Kilovar-hours)
● Harmonic (2~31st voltage&current)---Standard
● U (3-phase Voltage)
● I (3-phase Current)
● P (Power)
● Q (Reactive power)
● F (Frequency)
● S (Apparent power)
● PF (Power factor)
3m2v

Multi-rate/Flexible Tariff
● 4 Time zone
● 4 Tariff rate (Spike, Peak, Flat, Valley)
● 2 Time period list
● 14 Time period by day
● Data Frozen (last 48 months or last 90 days)
● Max demand and occurrence time
15033864g9

HMI for Common Configuration
● PT or CT ratio
● Wiring methods (3P4W or 3P3W)
● Back linght time
● RS485 (MODBUS-RTU) communication setting
5e5p

Benefits and Advantages

• High precision, CE and MID certification 

• Small size, light weight, easy to install 
• Diverse functions, full electric parameter measurement 
• Can realize wireless communication with the gateway module

DIMENSION

6bo2

Dimension of ADL400 (Current Input via Direct Connect)

图片7j91

Dimension of ADL400 (Current Input via CTs)

DISPLAY

8lkd

PACKAGE

Packaging Overview

(Minimum)

65bc4e464a69538350snv 

10j9j 

Packing Dimension and Weight

(Minimum)

 

Minimum Package Contain 1 pcs Products

Dimension: 170mm*150mm*130mm

 

Total N.W. (1 pcs)

0.66 KG

Packing Dimension and Weight

(Large)

 

Large Package Contain 36 pcs Products

Dimension: 540mm*480mm*280mm

Total G.W. (36 pcs)

10.09 KG

Average

Lead Time

 

Manufacturing: 3~4 days

(If paired with system need extra 1~2 days for adjustment)

 

Shippment: 8~9 days

(World Wide Shipment)

Product

HS Code

 

9028301400 

CO

Country of Origin

China

APPLICAITON

1705901510544dc8
17059015170119ut
1503386feh
1503386s1n

APPLICAITON SCENARIOS

150338602o
1503386qcw

Application in IoT System

150338646c

Installation

1503386193339916288_e98a310f8cb6131e1e1dd77ada8784db2nz

WIRING DIAGRAM

17gat
18hyk

ADL400 Direct Type Wiring&Installation Instruction (3P4W) 

ADL400 Direct Type Wiring&Installation Instruction (3P3W)

19hw1
20hmz

ADL400 CT Operated Type Wiring&Installation Instruction (3P4W)

ADL400 CT Operated Type Wiring&Installation Instruction (3P3W)

Direct Connect Type
1503386193339916288_e0aba75a0f747a7041dc7cd402a3edb61ob

PIN/Terminal Overview of ADL400 (Direct Connect Type)

1503386193339916288_c96388b68905355a52cc4226de1877ff66x
1503386193339916288_fc8b8548bdc32de1e94781635da0467f05d

Power Wiring: 3-phase 4-wire via direct connect

Power Wiring: 3-phase 3-wire via direct connect

1503386193339916288_b961121dd8ae39b4a1f2ba13229437a8zmq

RS485 Wired Communication of ADL400 (Direct Connect Type) with IoT Gateway

CT Operated Type
1503386193339916288_dbde0a6ec7a7bf885e0a05659b3f0fb5l7f

PIN/Terminal Overview of ADL400 (CT Operated Type)

1503386193339916288_a690ddaf83f4d3f1a8f2665323939337476
1503386193339916288_6269e42187fc5e0835be6691f64a7e22xgd

Power Wiring: 3-phase 4-wire CT operated

Power Wiring: 3-phase 3-wire CT operated

1503386193339916288_b961121dd8ae39b4a1f2ba13229437a8zmq

RS485 Wired Communication of ADL400 (CT Operated Type) with IoT Gateway

Installation Instruction Video


Download_file
[Datasheet | 2023.08.18] ADL400 3-phase DIN-Rail Energy...
Download_file
[Scenario Solution | 2023.07.14] Building Online Energy ....
Download_file
[Scenario Solution | 2023.07.14] Energy Meter Module ....
Download_file
[Basic Solution | 2023.08.18] IoT Cloud EMS Solution...
Download_file
[Basic Solution | 2023.08.18] IoT Cloud EMS Solution...
Download_file
[Instruction | 2023.08.19] ADL400 Direct Type Wiring &...
Download_file
[Instruction | 2023.08.18] ADL400 Direct Type Wiring & ....
Download_file
[Instruction | 2023.09.08] ADL400 Direct Ver + AWT100-...
Download_file
[Instruction | 2023.09.08] ADL400 Direct Ver + AWT100-4GH....
Download_file
[Instruction | 2023.09.08] ADL400 Direct Ver + AWT100-.....
Download_file
[Instruction | 2023.09.08] ADL400 Direct Ver + AWT100....
Download_file
[Instruction | 2023.08.18] ADL400 CT Operated Type Wiring ......
Download_file
[Instruction | 2023.08.18] ADL400 CT Operated Type Wiring ......
Download_file
[Instruction | 2023.09.08] ADL400 CT Ver + AWT100-4G.....
Download_file
[Instruction | 2023.09.08] ADL400 CT Ver + AWT100-4GHW......
Download_file
[Instruction | 2023.09.08] ADL400 CT Ver + AWT100-WiFiH
Download_file
[Instruction | 2023.09.08] ADL400 CT Ver + AWT100-WiFiHW ....
Download_file
[Instruction | 2023.10.13] ADL200 & ADL400 Common FAQ .....
Download_file
[Certificate | 2023.08.18] MID Certificate of ADL400 Series
Download_file
[Certificate | 2023.08.18] CE Certificate ADL400 Series
Download_file
[Certificate | 2023.08.18] EAC Certificate #1 of ADL400 Series
Download_file
[Certificate | 2023.08.18] EAC Certificate #2 of ADL400 Series